Enter/Exit Programming Mode Codabar
98 Magellan™ 800i Scanner
Check Character Verification
When enabled, the scanner will verify the check character of the labels. When
disabled, any check characters in a label are treated as data characters
007100(CR)
Disable Check Char Verification
DEFAULT
Enable Check Char Verification
007101(CR)
Check Character Transmit
Enable this option to transmit the check character with scanned bar code data.
Applies when the feature Check Character Verification on page 5-98 is enabled.
008C00(CR)
Disable Check Char Transmission
Enable Check Char Transmission
DEFAULT
008C01(CR)