Enter/Exit Programming Mode Codabar
98 Magellan™ 800i Scanner
Check Character Verification
When enabled, the scanner will verify the check character of the labels. When
disabled, any check characters in a label are treated as data characters
007100(CR)
Disable Check Char Verification
DEFAULT
Enable Check Char Verification
007101(CR)
Check Character Transmit
Enable this option to transmit the check character with scanned bar code data.
Applies when the feature Check Character Verification on page 5-98 is enabled.
008C00(CR)
Disable Check Char Transmission
Enable Check Char Transmission
DEFAULT
008C01(CR)

Table of Contents

Other manuals for Datalogic Magellan 800i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Magellan 800i and is the answer not in the manual?

Datalogic Magellan 800i Specifications

General IconGeneral
Scanner type2D
Yaw reading angle-60 - 60 °
Decoding standardsGS1 DataBar, Aztec Code, Data Matrix, MaxiCode, QR Code, GS1 DataBar Expanded Stacked, GS1 DataBar Stacked, GS1 DataBar Stacked Omnidirectional, MicroPDF417, PDF417
Tilt reading angle0 - 360 °
Optical sensor resolution752 pixels
Light levels (direct sunlight)0 - 86000 lx
BluetoothNo
Cable length2 m
Standard interfacesUSB
Input voltage5 V
Power consumption350 mA
Dimensions (WxDxH)76 x 109 x 151 mm
CertificationChina RoHS EU RoHS
Product colorWhite
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)5 - 95 %
Weight and Dimensions IconWeight and Dimensions
Weight306.2 g