Minimum Reads
This feature specifies the minimum number of consecutive times a Code 93
label must be decoded before it is accepted as a good read.
006E01(CR)
Minimum = 1 Read
DEFAULT
Minimum = 2 Reads
006E02(CR)
006E03(CR)
Minimum = 3 Reads
Minimum = 4 Reads
006E04(CR)
MSI/Plessey
The following options apply to the MSI/Plessey symbology.
Disable/Enable MSI/Plessey
When this feature is disabled, the scanner will not read MSI/Plessey bar codes.
00C100(CR)
Disable MSI/Plessey
DEFAULT
Enable MSI/Plessey
00C101(CR)

Table of Contents

Other manuals for Datalogic Magellan 800i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Magellan 800i and is the answer not in the manual?

Datalogic Magellan 800i Specifications

General IconGeneral
Scanner type2D
Yaw reading angle-60 - 60 °
Decoding standardsGS1 DataBar, Aztec Code, Data Matrix, MaxiCode, QR Code, GS1 DataBar Expanded Stacked, GS1 DataBar Stacked, GS1 DataBar Stacked Omnidirectional, MicroPDF417, PDF417
Tilt reading angle0 - 360 °
Optical sensor resolution752 pixels
Light levels (direct sunlight)0 - 86000 lx
BluetoothNo
Cable length2 m
Standard interfacesUSB
Input voltage5 V
Power consumption350 mA
Dimensions (WxDxH)76 x 109 x 151 mm
CertificationChina RoHS EU RoHS
Product colorWhite
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)5 - 95 %