Enter/Exit Programming Mode
Product Reference Guide
77
GS1 DataBar Expanded / Expanded Stacked
The following options apply to the GS1 DataBar Expanded symbology and are
only functional if the value-added feature for GS1 is activated.
Disable/Enable GS1 DataBar Expanded
When this feature is disabled, the scanner will not read GS1 DataBar Expanded
bar codes.
04D100(CR)
Disable GS1 DataBar Expanded
DEFAULT
Enable GS1 DataBar Expanded
04D101(CR)
GS1-128 Emulation
When enabled, GS1 DataBar Expanded bar codes will be translated to the GS1-
128 label data format.
04D500(CR)
Disable GS1-128 Emulation
DEFAULT
Enable GS1-128 Emulation
04D501(CR)