Enter/Exit Programming Mode
Product Reference Guide
129
Composite Labels
Disable/Enable GS1 DataBar Omnidirectional 2D Component
When enabled, if a GS1 DataBar Omnidirectional label is decoded which has the
2D linkage flag set, the 2D component must also be decoded or the base label
will be discarded.
When disabled, only the GS1 DataBar Omnidirectional base label will be
decoded and transmitted regardless of the state of the linkage flag.
Disable/Enable GS1 DataBar Expanded 2D Component
When enabled, if a GS1 DataBar Expanded label is decoded which has the 2D
linkage flag set, the 2D component must also be decoded or the base label will
be discarded.
When disabled, only the GS1 DataBar Expanded base label will be decoded and
transmitted regardless of the state of the linkage flag.
Disable GS1 DataBar Omnidirectional 2D Component
DEFAULT
Enable GS1 DataBar Omnidirectional 2D Component
04D600(CR)
04D601(CR)
Disable GS1 DataBar Expanded 2D Component
DEFAULT
Enable GS1 DataBar Expanded 2D Component
04D700(CR)
04D701(CR)