Enter/Exit Programming Mode
Product Reference Guide
103
Code 93
The following options apply to the Code 93 symbology.
Disable/Enable Code 93
When this feature is disabled, the scanner will not read Code 93 bar codes.
009100(CR)
Disable Code 93
DEFAULT
Enable Code 93
009101(CR)
Length Control
Fixed Length Decoding — When fixed length decoding is enabled, the scanner
will decode a bar code if the label length matches one of the configurable fixed
lengths.
Variable Length Decoding — When variable length decoding is enabled, the scan-
ner will decode a bar code if the label length falls in the range of the configu-
rable minimum and maximum le
ngth.
068700(CR)
Variable Length Decoding
DEFAULT
Fixed Length Decoding
068701(CR)