Code 39 Stitching
Enables/disables stitching for Code 39 labels. When parts of a Code 39 bar
code are presented to the scanner with this feature enabled, the bar code parts
will be assembled by the scanner’s software, and the data will be decoded if all
bar code proofing requirements are met.
00D100(CR)
Disable Code 39 Stitching
Enable Code 39 Stitching
DEFAULT
00D101(CR)
Minimum Reads
This feature specifies the minimum number of consecutive times a Code 39
label must be decoded before it is accepted as good read.
006B01(CR)
Minimum = 1 Read
DEFAULT
Minimum = 2 Reads
006B02(CR)
006B03(CR)
Minimum = 3 Reads
Minimum = 4 Reads
006B04(CR)

Table of Contents

Other manuals for Datalogic Magellan 800i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Magellan 800i and is the answer not in the manual?

Datalogic Magellan 800i Specifications

General IconGeneral
Scanner type2D
Yaw reading angle-60 - 60 °
Decoding standardsGS1 DataBar, Aztec Code, Data Matrix, MaxiCode, QR Code, GS1 DataBar Expanded Stacked, GS1 DataBar Stacked, GS1 DataBar Stacked Omnidirectional, MicroPDF417, PDF417
Tilt reading angle0 - 360 °
Optical sensor resolution752 pixels
Light levels (direct sunlight)0 - 86000 lx
BluetoothNo
Cable length2 m
Standard interfacesUSB
Input voltage5 V
Power consumption350 mA
Dimensions (WxDxH)76 x 109 x 151 mm
CertificationChina RoHS EU RoHS
Product colorWhite
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)5 - 95 %
Weight and Dimensions IconWeight and Dimensions
Weight306.2 g