Scale Features Enter/Exit Programming Mode
Product Reference Guide
171
Scale Interface Options
Specifies various tare and price-weight related scale options.
• Bit 0 = Don't transmit MT8213/MT8217 decimal point
• Bit 1 = Reserved for future use
• Bit 2 = Clear the tare after every weight request
• Bit 3 = Clear the unit price after every price-weight request
• Bit 4 = Consider a zero weight as under the minimum allowable value for
Dialog04 and Dialog06
1. Scan the Enter/Exit Programming Mode bar code.
2. Scan your selection from the bar codes below. You’ll need to cover any
unused bar codes on this and the facing page to ensure that the scanner
reads only the bar code you intend to scan.
3. Complete the programming sequence by scanning the Enter/Exit Pro-
gramming Mode bar code.
Scale Interface Options = default
Scale Interface Options =
Don't transmit MT8213/MT8217 decimal point
Scale Interface Options =
Clear the tare after every weight request
Scale Interface Options =
Clear the unit price after every price-weight request
Scale Interface Options = Consider a zero weight as under
the minimum allowable value for Dialog04 and Dialog06
DEFAULT