Enter/Exit Programming Mode
Product Reference Guide
201
ERI Timeout
Specifies the amount of time that an ERI signal is held in its active state for a
good read.
To set the ERI Timeout:
1. Scan the Enter/Exit Programming Mode bar code.
2. Scan the bar code, Set ERI Timeout on page 201 below. You’ll need to
cover any unused bar codes on this and the facing page to ensure that the
scanner reads only the bar code you intend to scan.
3. Scan the appropriate digits from the Keypad on page 461 in Appendix C
that represent the desired duration. The selectable range is 1-255, which
is the duration in 10-millisecond increments. Pad all single and double
digit numbers with leading zeros to yield a three-digit entry (001-255).
Examples:
000 = ERI timeout disabled
001 = 10ms
005 = 50ms
040 = 400ms
250 = 2,500ms (2.5 seconds)
4. The scanner will automatically exit Programming Mode when the appro-
priate amount of digits have been scanned.
NOTE
A setting of 0 (000) disables this feature.
Set ERI Timeout
Default setting for this feature is:
002 -20ms
DEFAULT