Enter/Exit Programming Mode EAS Features
192 Magellan™ 9300i / 9400i Scanners
EAS Retry Count
This feature sets the number of times the deactivation sequence (defined by the
feature, “EAS Deactivation Duration — Retry ”) is restarted after a failed deacti
-
vation attempt.
To set this feature:
1. Scan the Enter/Exit Programming Mode bar code.
2. Scan the bar code, Set EAS Retry Count on page 192 below. You’ll need to
cover any unused bar codes on this and the facing page to ensure that the
scanner reads only the bar code you intend to scan.
3. Scan the appropriate digits from the Keypad on page 461 in Appendix C
that represent the desired number. The selectable range is 0-15 resets.
Pad all single and double digit numbers with leading zeroes to yield a two-
digit entry (00-15).
4. Complete the programming sequence by scanning the Enter/Exit Pro-
gramming Mode bar code.
NOTE
A setting of zero specifies no deactivation retries upon failed
deactivation attempt.
Set EAS Retry Count
Default setting for this feature is:
03 - Retry EAS Deactivation three times
DEFAULT