Enter/Exit Programming Mode EAS Features
186 Magellan™ 9300i / 9400i Scanners
EAS Features — Sensormatic
EAS Mode
This controls the mode of operation for interfacing with the Sensormatic
®
AMB-
9010 or ScanMaxPro EAS controller box. Choices are:
• Disabled = EAS deactivation turned off.
• Coupled Mode = EAS tag is deactivated only upon successful scanning of
an item’s bar code or via EAS Exception Button.
• Decoupled Mode = EAS deactivation is performed independently of bar
code scanning.
• Hybrid Mode = EAS system is armed whenever the scanner is enabled and
the deactivation beep is sounded when an EAS tag is deactivated.
• Host Coupled Mode = Fundamental controls and notification of various
EAS events are provided to the POS system.
To set this feature:
1. Scan the Enter/Exit Programming Mode bar code.
2. Scan your selection from the bar codes below. You’ll need to cover any
unused bar codes on this and the facing page to ensure that the scanner
reads only the bar code you intend to scan.
3. Complete the programming sequence by scanning the Enter/Exit Pro-
gramming Mode bar code.
NOTE
These features control the Sensormatic® AMB-9010 or Scan-
MaxPro EAS controller box. This orderable option is installed at
the time of manufacture. See
"EAS Features — Checkpoint"
on page 200 to set options for the Checkpoint® EAS system.
NOTE
If the "Image Capture / CSS Button" on page 122 is enabled
simultaneously with the EAS Exception Button, precedence is
given to the CSS function. A momentary button push will acti
-
vate the CSS, while a one-second button push is required to
activate the EAS Exception function.
NOTE
Deactivation can only be initiated manually if the EAS Excep-
tion Button is armed to do so. Reference the feature "EAS
Exception Button" on page 193 for more information.
NOTE
If the "Image Capture / CSS Button" on page 122 is enabled
simultaneously with the EAS Exception Button, precedence is
given to the CSS function. A momentary button push will acti
-
vate the CSS, while a one-second button push is required to
activate the EAS Exception function.