Enter/Exit Programming Mode
Product Reference Guide
195
EAS Deactivation Duration — Coupled
Specifies the amount of time EAS deactivation is operative once the function has
been initiated following a bar code read.
To set the EAS Deactivation Duration — Coupled:
1. Scan the Enter/Exit Programming Mode bar code.
2. Scan the bar code, Set EAS Deactivation Duration — Coupled on page 195
below. You’ll need to cover any unused bar codes on this and the facing
page to ensure that the scanner reads only the bar code you intend to
scan.
3. Scan the appropriate digits from the Keypad on page 461 in Appendix C
that represent the desired duration. The selectable range is 1-255, which
is the duration in 10-millisecond increments. Pad all single and double
digit numbers with leading zeroes to yield a three-digit entry (001-255).
Examples:
005 = 50ms
040 = 400ms
250 = 2,500ms (2.5 seconds)
4. The scanner will automatically exit Programming Mode when the appro-
priate amount of digits have been scanned.
NOTE
This setting pertains only to units configured for EAS Coupled
Mode. Reference the
EAS Mode on page 186 description for
more information about Coupled and Decoupled EAS operation.
Set EAS Deactivation Duration — Coupled
Default setting for this feature is:
28 = 400ms
DEFAULT