Enter/Exit Programming Mode
Product Reference Guide
227
RS-232 Intercharacter Delay
Specifies delay between the end of one character and the beginning of the next
in 10-millisecond increments.
To set the RS-232 Intercharacter Delay:
1. Scan the Enter/Exit Programming Mode bar code.
2. Scan the bar code below, Set RS-232 Intercharacter Delay on page 227.
You’ll need to cover any unused bar codes on this and the facing page to
ensure that the scanner reads only the bar code you intend to scan.
3. Scan the appropriate digits from the Keypad on page 461 in Appendix C
that represent the desired delay. The selectable range is 0-100, which is
the delay in 10-millisecond increments. Pad all single and double digit
numbers with leading zeroes to yield a three-digit entry (000-100).
Examples:
001 = 10ms
005 = 50ms
040 = 400ms
100 = 1,000ms (1 second)
4. The scanner will automatically exit Programming Mode when the appro-
priate amount of digits have been scanned.
Set RS-232 Intercharacter Delay
Default setting for this feature is:
00 - No Intercharacter Delay
DEFAULT