Enter/Exit Programming Mode Interface Related Features
228 Magellan™ 9300i / 9400i Scanners
RS-232 Software Flow Control
Enables/disables RS-232 Flow Control using XON/ XOFF characters.
To set this feature:
1. Scan the Enter/Exit Programming Mode bar code.
2. Scan either the enable or disable bar code below. You’ll need to cover any
unused bar codes on this and the facing page to ensure that the scanner
reads only the bar code you intend to scan.
3. Complete the programming sequence by scanning the Enter/Exit Pro-
gramming Mode bar code.
NOTE
This item will be ignored when the feature,
RS-232 NAK Character, is enabled
RS-232 Software Flow Control= Disable
RS-232 Software Flow Control= Enable
DEFAULT