Enter/Exit Programming Mode
Product Reference Guide
241
RS-232 ACK NAK Error Handling
This item specifies the method the scanner will use to handle errors detected
while waiting to receive the ACK character from the host. Errors include unrec
-
ognized host commands and communication errors such as parity or framing
errors.
Ignore Errors (recommended setting)
Assume ACK (risk of lost label data)
Assume NAK (risk of duplicate label)
To select the option for RS-232 ACK NAK Error Handling:
1. Scan the Enter/Exit Programming Mode bar code.
2. Scan the desired option from the bar codes below. You’ll need to cover any
unused bar codes on this and the facing page to ensure that the scanner
reads only the bar code you intend to scan.
3. Complete the programming sequence by scanning the Enter/Exit Pro-
gramming Mode bar code.
RS-232 ACK NAK Error Handling = Ignore Errors
RS-232 ACK NAK Error Handling = Assume ACK
RS-232 ACK NAK Error Handling = Assume NAK
DEFAULT
032300(CR)
032301(CR)
032302(CR)

Table of Contents

Other manuals for Datalogic Magellan 9400i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Magellan 9400i and is the answer not in the manual?

Datalogic Magellan 9400i Specifications

General IconGeneral
Standard interfacesUSB
Connectivity technologyWired
TypeBuilt-in bar code reader
Sensor typeLinear
Scanner type1D/2D
Light levels (direct sunlight)0 - 86080 lx
Linear (1D) barcodes supportedGS1 DataBar Expanded, GS1 DataBar Omnidirectional, JAN, U.P.C.
2D (matrix & stacked) barcodes supportedAztec Code, Data Matrix, Micro QR Code, QR Code, Small Aztec Code
Input voltage100 - 240 V
Input frequency50 - 60 Hz
Power source typeAC
Power consumption (standby)11 W
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)10 - 40 °C
Operating relative humidity (H-H)5 - 95 %
Product colorBlack, Grey
Housing material-
Sustainability certificatesRoHS
Weight and Dimensions IconWeight and Dimensions
Depth102 mm
Width401 mm
Height130 mm
Weight- g

Related product manuals