1D Symbologies Enter/Exit Programming Mode
Product Reference Guide   
 
   123
GS1 DataBar Expanded Set Length 2
This feature specifies one of the bar code lengths for GS1 DataBar Expanded 
Length Control on page 122. Length 2 is the maximum label length if in Vari-
able Length on page 122 Mode, or the second fixed length if in Fixed Length on 
page 122 Mode. Length includes the bar code’s data char
acters only.
The length can be set from 1 to 74 characters. A setting of 00 specifies to 
ignore this length (only one fixed length). See "Set Length 2" on
 page 250 for 
more detailed progr
amming instructions.
Select GS1 DataBar Expanded Set Length 2 Setting
To configure this feature, scan the ENTER/EXIT bar code 
above, then the bar code at left followed by digits from 
the Alphanumeric characters in 
Appendix D, Key-
pad
 representing your desired character(s). End by 
scanning the ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort and 
not save 
the entry string. You can then start again at the 
beginning.
CANCEL
DEFAULT
74 = Length 2 is 74 Characters
$CXBL2
~