Enter/Exit Programming Mode
Product Reference Guide
21
Global Interface Features
The following interface features are configurable by all interface types. To set
features specific to your interface, turn to that section of this manual.
HOST COMMANDS — OBEY/IGNORE
on page 21
USB SUSPEND MODE
on page 22
Host Commands — Obey/Ignore
This option specifies whether the scanner will obey or ignore host commands.
When set to ignore, the scanner will ignore all host commands except for those
necessary for:
•service mode
flash programming mode
•keeping the inte
rface active
transmission of labels.
Host Commands = Obey
Host Commands = Ignore
DEFAULT
$CIFIH00
$CIFIH01