1D Symbologies Enter/Exit Programming Mode
Product Reference Guide
173
Industrial 2 of 5 Set Length 2
This feature specifies one of the bar code lengths for Industrial 2 of 5 Length
Control on page 171. Length 2 is the maximum label length if in Variable
Length on page 130 Mode, or the second fixed l
ength if in Fixed Length on
page 130 Mode. Length includes the bar code’s check, data
, and full-ASCII shift
characters. The length does not include start/stop
characters.
The length can be set from 1 to 50 characters. A setting of 00 specifies to
ig
nore this length (only one fixed length). See "Set Length 2" on
page 250 for
more detailed progr
amming instructions.
Select Industrial 2 of 5 Length 2 Setting
To configure this feature, scan the ENTER/EXIT bar code
above, then the bar code at left followed by digits from
the Alphanumeric characters in
Appendix D, Key-
pad
representing your desired character(s). End by
scanning the ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
CANCEL
DEFAULT
50 = Length 2 is 50 Characters
$CU2L2
~