Scanning Features
Scan Mode
Selects the scan operating mode for the reader. Selections are:
Trigger Single:
When the trigger is pulled, scanning is activated until one of the
following occurs:
•
Scanning Active Time
has elapsed
• a label has been read
• the trigger is released
This mode is associated with typical handheld reader operation: when the trig-
ger is pulled, scanning starts and the product scans until the trigger is released,
or a labe
l is read, or the maximum
Scanning Active Time
has elapsed.
Trigger Hold Multiple :
When the trigger is pulled, scanning starts and the product
scans until the trigger is released or
Scanning Active Time
has elapsed. Reading a
label does not dis
able scanning.
Double Read Timeout
prevents undesired multi-
ple reads of the same label while in this mode.
Trigger Pulse Multiple:
When the trigger is pulled, continuous scanning is acti-
vated until
Scanning Active Time
has elapsed or the trigger has been released and
pulled again.
Double Read Timeout
prevents undesired multiple reads of the
same label while in this mode.
Scanning Active Time
This setting specifies the amount of time that the reader stays in scan ON state
once the state is entered. The range for this setting is from 1 to 255 seconds in
1-second increments.
Follow these instructions to set this feature:
1. Determine the desired setting.
2. Pad the result with leading zeroes to yield three digits. For example: 0 =
0
00, 5 = 005, 20 = 020, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Program-
ming Mode.
4. Scan the bar code: SELECT SCANNING ACTIVE
TIME SETTING on
page 103
.
5. Scan the appropriate three digits from the keypad in
Appendix D, Keypad
that represent the duration which was determined in the steps above. You
wil
l hear a two-beep indication after the last character.
NOTE
If you make a mistake before the last
character, scan the CANCEL bar
code to abort and not save the entry string. You can then start again
at the beginning.