1D Symbologies Enter/Exit Programming Mode
Product Reference Guide
133
Code 32 (Italian Pharmaceutical)
The following options apply to the Code 32 symbology.
Code 32 Enable/Disable
When disabled, the scanner will not read Code 32 bar codes.
DEFAULT
Code 32 = Disable
Code 32 = Enable
Code 32 Feature Setting Exceptions
NOTE
The following features are set for Code 32 by using these Code 39 set-
tings:
"Code 39 Quiet Zones"
on page 129
"Code 39 Length Control"
on page 130
Code 32 Check Character Transmission
Enable this option to transmit the check character along with Code 32 bar code
data.
DEFAULT
Code 32 Check Character Transmission = Don’t Send
Code 32 Check Character Transmission = Send
$CP3EN00
$CP3EN01
$CP3CT00