5 Applied Instructions and Basic Usage
Data transmission registers in the DVP-10PM series motion controller
(message sent by the DVP-10PM series motion controller):
Register Data Description
D1089 low ‘0’ 30 H ADR 1
D1089 high ‘1’ 31 H ADR 0
ADR (1,0): Address of the
VFD-B series AC motor
drive
D1090 low ‘0’ 30 H CMD 1
D1090 high ‘3’ 33 H CMD 0
CMD (1,0): Command
code
D1091 low ‘2’ 32 H
D1091 high ‘1’ 31 H
D1092 low ‘0’ 30 H
D1092 high ‘1’ 31 H
Starting data address
D1093 low ‘0’ 30 H
D1093 high ‘0’ 30 H
D1094 low ‘0’ 30 H
D1094 high ‘6’ 36 H
Quantity of data (count by the word)
D1095 low ‘D’ 44 H LRC CHK 1
D1095 high ‘4’ 34 H LRC CHK 0
LRC CHK (0,1):
Checksum
Data reception reigsters in the DVP-10PM series motion controller (message
with which the VFD-B series AC motor drive responds):
Register Data Description
D1070 low ‘0’ 30 H ADR 1
D1070 high ‘1’ 31 H ADR 0
D1071 low ‘0’ 30 H CMD 1
D1071 high ‘3’ 33 H CMD 0
D1072 low ‘0’ 30 H
D1072 high ‘C’ 43 H
Quantity of data (count by the byte)
D1073 low ‘0’ 30 H
D1073 high ‘1’ 31 H
D1074 low ‘0’ 30 H
D1074 high ‘0’ 30 H
Contents of the
address 2101 H
The DVP-10PM series
motion controller
automatically converts
the ASCII characters
into values, and store
the values in D1050.
(D1050=0100 H)
D1075 low ‘1’ 31 H
D1075 high ‘7’ 37 H
D1076 low ‘6’ 36 H
D1076 high ‘6’ 36 H
Contents of the
address 2102 H
The DVP-10PM series
motion controller
automatically converts
the ASCII characters
into values, and store
the values in D1051.
(D1051=1766 H)
D1077 low ‘0’ 30 H
D1077 high ‘0’ 30 H
D1078 low ‘0’ 30 H
D1078 high ‘0’ 30 H
Contents of the
address 2103 H
The DVP-10PM series
motion controller
automatically converts
the ASCII characters
into values, and store
the values in D1052.
(D1052=0000 H)
D1079 low ‘0’ 30 H
D1079 high ‘0’ 30 H
D1080 low ‘0’ 30 H
D1080 high ‘0’ 30 H
Contents of the
address 2104 H
The DVP-10PM series
motion controller
automatically converts
the ASCII characters
into values, and store
the values in D1053.
(D1053=0000 H)