DVP-20PM series motion controller VFD-B series AC motor drive: The
DVP-20PM series motion controller sends “01 06 0100 1770 71”.
VFD-B series AC motor drive DVP-20PM series motion controller: The
DVP-20PM series motion controller receives “01 06 0100 1770 71”.
Data transmission registers in the DVP-20PM series motion controller
(message sent by the DVP-20PM series motion controller):
Register Data Description
D1089 low ‘0’ 30 H ADR 1
D1089 high ‘1’ 31 H ADR 0
ADR (1,0): Address of the
VFD-B series AC motor drive
D1090 low ‘0’ 30 H CMD 1
D1090 high ‘6’ 36 H CMD 0
CMD (1,0): Command code
D1091 low ‘0’ 30 H
D1091 high ‘1’ 31 H
D1092 low ‘0’ 30 H
D1092 high ‘0’ 30 H
Data address
D1093 low ‘1’ 31 H
D1093 high ‘7’ 37 H
D1094 low ‘7’ 37 H
D1094 high ‘0’ 30 H
Data
D1095 low ‘7’ 37 H LRC CHK 1
D1095 high ‘1’ 31 H LRC CHK 0
LRC CHK (0,1): Checksum
Data reception reigsters in the DVP-10PM series motion controller (message
with which the VFD-B series AC motor drive responds):
Register Data Description
D1070 low ‘0’ 30 H ADR 1
D1070 high ‘1’ 31 H ADR 0
D1071 low ‘0’ 30 H CMD 1
D1071 high ‘6’ 36 H CMD 0
D1072 low ‘0’ 30 H
D1072 high ‘1’ 31 H
D1073 low ‘0’ 30 H
D1073 high ‘0’ 30 H
Data address
D1074 low ‘1’ 31 H
D1074 high ‘7’ 37 H
D1075 low ‘7’ 37 H
D1075 high ‘0’ 30 H
Data
D1076 low ‘7’ 37 H LRC CHK 1
D1076 high ‘1’ 31 H LRC CHK 0