6 Basic Usage of Motion Instructions and G-codes
DVP-20PM Application
Manual
6-8
DVP20OM00D supports two-axis (X-axis/Y-axis) high-speed positioning, and
therefore there are 8 operand combinations for DRV.
No.
Motion
instruction
Combination of operands
1
X
P
1
2
X
P
1
FX V
1
3
Y P
2
4
Y
P
2
FY V
2
5
X
P
1
Y P
2
6
X
P
1
Y P
2
FY V
2
7
X
P
1
FX V
1
Y
P
2
8
DRV
X
P
1
FX V
1
Y P
2
FY V
2
DVP20PM00M supports 3-axis (X-axis/Y-axis/Z-axis) high-speed positioning, and
therefore there are 26 operand combinations for DRV.
No.
Motion
instruction
Combination of operands
1
X
P
1
2
X
P
1
FX V
1
3
Y P
2
4
Y
P
2
FY V
2
5
X
P
1
Y P
2
6
X
P
1
Y P
2
FY V
2
7
X
P
1
FX V
1
Y
P
2
8
X
P
1
FX V
1
Y P
2
FY V
2
9
Z P
3
10
X
P
1
Z P
3
11
X
P
1
FX V
1
Z P
3
12
Y P
2
Z P
3
13
Y
P
2
FY V
2
Z P
3
14
X
P
1
Y P
2
Z P
3
15
X
P
1
Y P
2
FY V
2
Z P
3
16
X
P
1
FX V
1
Y
P
2
Z P
3
17
X
P
1
FX V
1
Y P
2
FY V
2
Z P
3
18
Z P
3
FZ V
3
19
X
P
1
Z P
3
FZ V
3
20
X
P
1
FX V
1
Z P
3
FZ V
3
21
Y P
2
Z P
3
FZ V
3
22
Y
P
2
FY V
2
Z P
3
FZ V
3
23
X
P
1
Y P
2
Z P
3
FZ V
3
24
X
P
1
Y P
2
FY V
2
Z P
3
FZ V
3
25
X
P
1
FX V
1
Y
P
2
Z P
3
FZ V
3
26
DRV
X
P
1
FX V
1
Y P
2
FY V
2
Z P
3
FZ V
3
If users set the target position on the axis without setting the moving speed, the
operation will run at V