10 Application of G-codes
4. Enabling the dispensing operation: Execute the G-codes/M-codes in CAM chart. Work modes of 3
axes should be set up first and select the CAM chart to be executed. Set D1846=H2000 to enable
cyclic E-CAM. When the operation in CAM chart is completed, M1792 will be rising-edge triggered.
(A) Setting up work modes of 3 axes: If the work modes are set up as H1000 already, skip this step.
X-axis Y-axis Z-axis
Work mode (bit 12) D1847=H1000 D1927=H1000 D2007=H1000
(B) Enabling the dispensing operation by executing the Oxn subroutine
a. Calling the Ox0 subroutine
b. Calling the Ox1 subroutine
c. Calling the Ox2 subroutine
DVP-20PM Application Manual
10-15