Delta DVP-20PM - Page 54

Delta DVP-20PM
580 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3 Devices
Special
M
device
Function 20D 20M
Off
On
STOP
RUN
RUN
STOP
Attribute Latching Default Page
M1246
C246: Selecting a mode of counting (On: Counting
down)
Off - - R No Off -
M1247
C247: Selecting a mode of counting (On: Counting
down)
Off - - R No Off -
M1248
C248: Selecting a mode of counting (On: Counting
down)
Off - - R No Off -
M1249
C249: Selecting a mode of counting (On: Counting
down)
Off - - R No Off -
M1250
C250: Selecting a mode of counting (On: Counting
down)
Off - - R No Off -
M1251
C251: Selecting a mode of counting (On: Counting
down)
Off - - R No Off -
M1252
C252: Selecting a mode of counting (On: Counting
down)
Off - - R No Off -
M1253
C253: Selecting a mode of counting (On: Counting
down)
Off - - R No Off -
M1254
C254: Selecting a mode of counting (On: Counting
down)
Off - - R No Off -
M1255
C255: Selecting a mode of counting (On: Counting
down)
Off - - R No Off -
M1303
Interchanging high bits with low bits when XCH is
executed
Off - - R/W No Off
M1304* The input terminals can be set to ON or OFF. Off - - R/W No Off 3-35
M1744* Resetting the M-code in the Ox motion subroutine Off Off - R/W No Off 3-36
M1745
Disabling the X-axis from returning home in the Ox
motion subroutine
Off - - R/W No Off -
M1746
Setting the signal for starting the noncyclic
electronic cam motion
Off R/W No Off -
M1748 Stopping the electronic cam motion Off R No Off -
M1749
Controlling the maximum frequency of pulses sent
by the electronic cam
Off - - R/W No Off -
M1751
Enabling the writing of the present command
position of the X-axis
Off - - R/W No Off 3-36
The electronic cam does not start at zero.
M1752
Immediately stopping the noncyclic electronic cam
motion when there is a transition in DOG’s signal
from low to high or form high to low
Off - - R/W No Off -
M1755
Switching the source of the master axis of the
noncyclic electronic cam
Off - - R/W No Off -
M1756
The reference terminals for the synchronization
output terminals are X0 (CLR0=Off) and X1 (CLR1=
Off).
Off - - R/W No Off -
M1757
The present speed of the electronic cam remains
unchanged.
Off - - R/W No Off -
M1760
Using a radian or a degree in the Ox motion
subroutine
Off - - R/W No Off -
M1761 The X-axis stops at the angle specified. Off - - R/W No Off 3-36
M1792 The X-axis is ready. On On On R No On 3-36
M1793*
X-axis motion error flag (It is reset at the time when
the X-axis operates.)
Off - - R/W No Off 3-37
M1794*
If an M code in an Ox motion subroutine is
executed, M1794 will be ON. (M1974 is reset to
OFF at the time when the Ox motion subroutine is
executed.)
Off - Off R No Off 3-36
M1795
If M0 in an Ox motion subroutine is executed,
M1795 will be ON. (M1795 is reset to OFF at the
times when the Ox motion subroutine is executed.)
Off - - R No Off -
M1796
If M02 in an Ox motion subroutine is executed,
M1796 will be ON. (M1796 is reset to OFF at the
time when the Ox motion subroutine is executed.)
Off On - R No Off -
DVP-20PM Application Manual
3-18