3 Devices
DVP-20PM Application Manual
3-21
Special
D
device
Function 20D 20M
Off
On
STOP
RUN
RUN
STOP
Attribute Latching Default Page
D1130
Error code that a slave station sends by means
of Modbus when the RS-485 port on the
DVP-20PM series motion controller functions as
a master station
0 0 - R No 0 -
D1140*
Number of right-side modules (8 right-side
modules at most)
0 - - R No 0 3-35
D1142* Number of X devices in a digital module 0 - - R No 0 3-35
D1143* Number of Y devices in a digital module 0 - - R No 0 3-35
D1149
ID of a function card (0: No card inserted; 3:
COM3; 8: 2AD; 9: 2DA)
0 - - R No 0 -
D1200* Starting latching auxiliary relay address - - - R/W Yes 500 3-35
D1201* Terminal latching auxiliary relay address - - - R/W Yes 999 3-35
D1202* Starting latching timer address - - - R/W Yes -1 3-35
D1203* Terminal latching timer address - - - R/W Yes -1 3-35
D1204* Starting latching 16-bit counter address - - - R/W Yes 100 3-35
D1205* Terminal latching 16-bit counter address - - - R/W Yes 199 3-35
D1206* Starting latching 32-bit counter address - - - R/W Yes 220 3-35
D1207* Terminal latching 32-bit counter address - - - R/W Yes 255 3-35
D1208* Starting latching stepping relay address - - - R/W Yes 500 3-35
D1209* Terminal latching stepping relay address - - - R/W Yes 1023 3-35
D1210* Starting latching data register address - - - R/W Yes 200 3-35
D1211* Terminal latching data register address - - - R/W Yes 9999 3-35
D1313*
Value of the second in the real-time clock (RTC):
00~59
- - - R/W Yes 0 -
D1314*
Value of the minute in the real-time clock (RTC):
00~59
- - - R/W Yes 0 -
D1315*
Value of the hour in the real-time clock (RTC):
00~23
- - - R/W Yes 0 -
D1316*
Value of the day in the real-time clock (RTC):
1~31
- - - R/W Yes 1 -
D1317*
Value of the month in the real-time clock (RTC):
01~12
- - - R/W Yes 1 -
D1318*
Value of the week in the real-time clock (RTC):
1~7
- - - R/W Yes 2/5 -
D1319*
Value of the year in the real-time clock (RTC):
00~99 (A.D.)
- - - R/W Yes 8/10 -
D1320* ID of the first right-side module 0 - - R No 0 3-35
D1321* ID of the second right-side module 0 - - R No 0 3-35
D1322* ID of the third right-side module 0 - - R No 0 3-35
D1323* ID of the fourth right-side module 0 - - R No 0 3-35
D1324* ID of the fifth right-side module 0 - - R No 0 3-35
D1325* ID of the sixth right-side module 0 - - R No 0 3-35
D1326* ID of the seventh right-side module 0 - - R No 0 3-35
D1327* ID of the eighth right-side module 0 - - R No 0 3-35
D1328*
Target position of the third axis controlled by G00
and G01 (low word)
D1329*
Target position of the third axis controlled by G00
and G01 (High word)
0 - - R/W No
0
-
Maximum speed of the third axis controlled by
G00 (low word)
-
D1330*
Speed of the interpolation executed by the third
axis controlled by G01 (low word)
0 - - R/W No
0
-
Maximum speed of the third axis controlled by
G00 (high word)
-
D1331*
Speed of the interpolation executed by the third
axis controlled by G01 (high word)
0 - - R/W No
0
-
D1400 Enabling the interrupt 0 - - R/W No 0 3-35
D1401 Cycle of the time interrupt (Unit: ms) 0 - - R/W No 0 3-35