TEST ACTION APPLICABILITY
4 Turn the ignition off.
Disconnect the Remote Keyless Entry Module connector.
Disconnect the Door Lock Switch connector.
Measure the resistance of the appropriate Door Switch Mux circuit between the RKE
connector and the Door Lock Switch connector.
Is the resistance below 5.0 ohms?
All
Yes → Go To 5
No → Repair the Door Switch Mux wire for an open.
Perform BODY VERIFICATION TEST - VER 1.
5 If there are no possible causes remaining, view repair. All
Repair
Replace the Door Lock Switch - open resistor.
Perform BODY VERIFICATION TEST - VER 1.
6 Turn the ignition off.
Disconnect the Remote Keyless Entry Module connector.
Disconnect the Door Lock Switch connector.
Measure the voltage between the appropriate Door Switch Mux circuit and ground.
Is there any voltage present?
All
Yes → Repair the Door Switch Mux wire for a short to voltage.
Perform BODY VERIFICATION TEST - VER 1.
No → Replace the Remote Keyless Entry module.
Perform BODY VERIFICATION TEST - VER 1.
201
POWER DOOR LOCKS/RKE
*ALL LOCKS INOPERATIVE FROM A DOOR LOCK SWITCH — Continued