Symptom:
MODULE PREVIOUSLY CONFIGURED FOR VTSS
When Monitored and Set Condition:
MODULE PREVIOUSLY CONFIGURED FOR VTSS
When Monitored: With the ignition on during the configuration of the Remote Keyless
Entry Module.
Set Condition: If the configuration of the module type has been previously set for VTSS,
an attempt to set the module for non-VTSS will cause the new configuration to fail. This
code should only appear if attempting to re-configure a used RKE module.
POSSIBLE CAUSES
REMOTE KEYLESS ENTRY MODULE
TEST ACTION APPLICABILITY
1 The RKE module attempting to be configured to non-VTSS, has originally been
configured to be used on a VTSS equipped vehicle.
If the vehicle is NOT VTSS equipped (does not have either a hood ajar or a decklid
security switch (knockout)) the RKE module attempting to be configured should be
replaced.
If there are no possible causes remaining, view repair.
All
Repair
Replace the Remote Keyless Entry Module.
Perform VTSS VERIFICATION TEST - 1A.
215
VEHICLE THEFT/SECURITY