Symptom:
PASSENGER DOOR SWITCH FAILURE
When Monitored and Set Condition:
PASSENGER DOOR SWITCH FAILURE
When Monitored: Whenever the RKE module is connected and battery voltage is above
10.0 volts.
Set Condition: When a lock or unlock input from the passenger door switch to the RKE
module is present for more than 8 seconds.
POSSIBLE CAUSES
DTC PRESENT
REMOTE KEYLESS ENTRY MODULE - SHORTED
DOOR LOCK SWITCH SHORTED
CYLINDER LOCK SWITCH SHORTED - EXPORT ONLY
PASSENGER DOOR SWITCH MUX CIRCUIT SHORT TO GROUND.
TEST ACTION APPLICABILITY
1 Turn the ignition on.
With the DRBIIIt, erase DTCs.
Operate the door locks several times from the passenger door lock switch and the
cylinder lock switch if VTSS equipped..
With the DRBIIIt, read DTCs.
Does the DRBIIIt display: PASS DOOR SWITCH FAILURE?
All
Yes → Go To 2
No → The causes for setting this code are not present at thistime. Using
the wiring diagram/schematic as a guide, inspect the wiring and
connectors.
Perform BODY VERIFICATION TEST - VER 1.
2 Disconnect the Remote Keyless Entry module connector.
Turn the ignition off.
Measure the resistance between ground and the passenger Door Switch Mux circuit
(cavity 11) in the RKE module connector
Is the resistance below 8000.0 ohms?
All
Yes → Go To 3
No → Replace the Remote Keyless Entry module.
Perform BODY VERIFICATION TEST - VER 1.