Symptom:
INCORRECT MODULE TYPE CONFIGURATION FOR PART NUM-
BER
When Monitored and Set Condition:
INCORRECT MODULE TYPE CONFIGURATION FOR PART NUMBER
When Monitored: When the ignition is in the run position during Remote Keyless Entry
Module configuration.
Set Condition: When the operator attempts to choose a configuration which is not
compatible with the part number. Example: Selecting BUX RKE when the module is a
Domestic part number, The RKE frequencies are not compatible.
POSSIBLE CAUSES
INCORRECT MODULE TYPE CONFIGURATION FOR PART NUMBER
TEST ACTION APPLICABILITY
1 Ensure the module type corresponds with the correct module part number.
If the module type corresponds with the module part number the RKE module is
defective.
If there are no possible causes remaining, view repair.
All
Repair
Replace the Remote Keyless Entry Module.
Perform BODY VERIFICATION TEST - VER 1.
183
POWER DOOR LOCKS/RKE