TEST ACTION APPLICABILITY
3 With the DRBIIIt, perform the SRI Memory Test a second time.
NOTE: Retest the SRI Memory two more times.
Does the DRBIIIt display Write Refused again?
All
Yes → Replace and program the Powertrain Control Module in accor-
dance with the Service Information.
Perform POWERTRAIN VERIFICATION TEST VER - 1.
No → Test Complete.
4 With the DRBIIIt, perform the SRI Memory Test.
Does the DRBIIIt display SRI Mileage Invalid?
All
Yes → Update the mileage and retest the SRI Memory.
Perform POWERTRAIN VERIFICATION TEST VER - 1.
No → Go To 5
5 Compare the SRI Mileage stored with the Instrument Panel Odometer.
Is the mileage within the specified range displayed on the DRBIIIt?
All
Yes → Test Complete.
No → Update the mileage and retest the SRI Memory.
Perform POWERTRAIN VERIFICATION TEST VER - 1.
265
DRIVEABILITY - NGC
P1696-EEPROM MEMORY WRITE DENIED/INVALID — Continued