TEST ACTION APPLICABILITY
7 If there are no possible causes remaining, view repair. All
Repair
Replace the Fuel Pump Module.
Perform POWERTRAIN VERIFICATION TEST VER - 1.
8 Turn the ignition off.
Remove the Fuel Pump Relay from the PDC.
With a 12 volt test light connected to ground, probe the Fuel Pump Relay Fused B+
circuit at the PDC.
Does the test light illuminate?
All
Yes Go To 9
No Repair the Fuel Pump Realy Fused B+ circuit. Check for open fuse
in the PDC.
Perform POWERTRAIN VERIFICATION TEST VER - 1.
9 Turn the ignition off.
Remove the Fuel Pump Relay from the PDC.
Disconnect the Fuel Pump Module harness connector.
NOTE: Check connectors - It is critical that the connector is free from any
signs of corrosion or deformities
Measure the resistance of the (A141) Fuel Pump Relay Output circuit from the relay
connector to the fuel pump module connector.
Is the resistance below 5.0 ohms?
All
Yes Replace the Fuel Pump Relay.
Perform POWERTRAIN VERIFICATION TEST VER - 1.
No Repair the (A141) Fuel Pump Relay Output circuit for an open.
Perform POWERTRAIN VERIFICATION TEST VER - 1.
313
STARTING
*CHECKING FUEL DELIVERY Continued