Page 100 • 700120S • ENTRON Controls, LLC.
Although the control will automatically adjust the amplifiers gain to achieve best current control
quality, improper choice of Current Sensor or
rr
rr
r
.A..A.
.A..A.
.A. value will cause overshooting or poor
compensation quality during the Current Compensation process.
MONITORING
With
C.rC.r
C.rC.r
C.r
..
..
.=
1313
1313
13,
1515
1515
15,
1717
1717
17 or
1919
1919
19 if using PT2, PT5, PT10 or PT20 as Current Sensor, the control will
operate in PRIMARY PRESET-RANGE MONITORING mode. When the control operates in
this MONITORING mode, the control will only display the weld current after a weld but will
not compensate the current error. The value of CURRENT setting in the weld schedules should
be input as the percentage of maximum current output of the control.
8.2.3 SECONDARY AUTO-RANGE COMPENSATION OR MONITORING
MODE WITH ROGOWSKI COIL
In these modes, a learning-type setup process is required. With this learning-type setup process,
the control will record the current values of maximum output, and constant current compensation
will be based on this data. The learning-type setup process is described in Section 8.4. Normally
these modes are used only when the current range of control is unavailable.
COMPENSATION
With
C.rC.r
C.rC.r
C.r
..
..
.=
3030
3030
30, the control will operate in SECONDARY AUTO-RANGE COMPENSATION
mode with Rogowski Coil. When the control operates in this COMPENSATION mode and if
rr
rr
r
.A..A.
.A..A.
.A.=
00.9900.99
00.9900.99
00.99, the value of PERCENT CURRENT setting in the weld schedules should be input as
the percentage [%] of maximum current output of the control. Otherwise,
rr
rr
r
.A..A.
.A..A.
.A. should be set to
the assumed maximum secondary CURRENT in [kA] value, and the value of PERCENT
CURRENT setting in the weld schedules should be input as the required secondary output
current in [kA] value of the control.
MONITORING
With
C.rC.r
C.rC.r
C.r
..
..
.=
3131
3131
31, the control will operate in SECONDARY AUTO-RANGE MONITORING mode
with Rogowski Coil. When the control operates in this MONITORING mode, the control will
only display the welding current after a weld but will not compensate the current error. The
value of PERCENT CURRENT setting in the weld schedules should be input as the percentage
[%] of maximum current output of the control.
8.2.4 PRIMARY AUTO-RANGE COMPENSATION OR MONITORING MODE
WITH CURRENT TRANSFORMER
In these modes, a learning-type setup process is required. With a learning-type setup process,
the control will record the current values of maximum output, and constant current compensation
will be based on this data. The learning-type setup process is described in Section 8.4. Normally
these modes are only used when the current range of control is unavailable.
8.2.2 PRIMARY PRESET-RANGE COMPENSATION OR MONITORING
MODE (cont.)