7.2.5 QUICK SETUP INSTRUCTIONS FOR STEPPER
For basic single schedule welding where weld time and/or percent current will need to increase
after a given quantity of welds, follow these steps:
1. Put control in PROGRAM mode.
2. In EXTENDED FUNCTIONS (
EFEF
EFEF
EF), set
S.t.S.t.
S.t.S.t.
S.t. =
0101
0101
01.
3. Select desired starting schedule (00, 10, 20, 30, or 40).
4. Program all SCHEDULE parameters – SQUEEZE, WELD/HEAT, PERCENT CURRENT,
HOLD, etc.
5. Press SELECT push button, moving indicator LED to WELD/HEAT parameter.
6. Select first weld step for schedule by pressing SCHEDULE push buttons until desired weld
step is displayed:
If using schedule 00, select weld step
a.0a.0
a.0a.0
a.0
If using schedule 10, select weld step
b.0b.0
b.0b.0
b.0
If using schedule 20, select weld step
C.0C.0
C.0C.0
C.0
If using schedule 30, select weld step
d.0d.0
d.0d.0
d.0
If using schedule 40, select weld step
E.0E.0
E.0E.0
E.0
7. Program required WELD COUNT for this step as follows:
Press and hold left DATA push button to enter 1000s digit.
Press and release quickly left DATA push button to enter 100s digit.
Press and hold right DATA push button to enter 10s digit.
Press and release quickly right DATA push button to enter 1s digit.
Press ENTER when done and then press SELECT push button.
8. Copy this schedule by pressing and holding ENTER and right SCHEDULE push button.
Repeat copying of this schedule for as many steps needed for that stepper.
9. Change each schedule’s WELD/HEAT and/or PERCENT CURRENT as required.
10. Return to starting schedule (00, 10, 20 30 or 40). Reset stepper by pressing and holding
ENTER and pressing both DATA push buttons simultaneously.
11. Put control in OPERATE mode and begin welding.
12. Return to the first starting schedule.
After all weld steps are complete, control will stop and display
S.t.S.t.
S.t.S.t.
S.t.
E.n.d.E.n.d.
E.n.d.E.n.d.
E.n.d.
When using
S.t.S.t.
S.t.S.t.
S.t.=
0202
0202
02 with multiple steppers, all steppers must be reset.
To reset stepper, repeat steps 10 and 11. Control must be in PROGRAM mode for step 10.
NOTICE

Table of Contents

Other manuals for Entron EN1000 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Entron EN1000 series and is the answer not in the manual?

Entron EN1000 series Specifications

General IconGeneral
BrandEntron
ModelEN1000 series
CategoryController
LanguageEnglish

Related product manuals