Page 102 • 700120S • ENTRON Controls, LLC.
Tap UP (or Range DOWN) indicator (
t-UPt-UP
t-UPt-UP
t-UP) – Shown at the end of a weld sequence if the
weld control is unable to compensate and maintain the programmed CURRENT. In this
case, moving the tap selector, if exists, to a higher setting will allow the control to maintain
the current constant. If machine is already at the highest tap setting, the maximum current
range of machine is much lower than the programmed range in
rr
rr
r
.A..A.
.A..A.
.A. In this case, choose a
lower current range from Table 8-1 and program the corresponding value in
rr
rr
r
.A..A.
.A..A.
.A.
PHASE SHIFT in [%] and RMS CURRENT in [kA] are also available during this condition.
To show PERCENT while
t-UPt-UP
t-UPt-UP
t-UP is displayed, simply press the DATA 1s push button. To
show the RMS CURRENT in [kA], simply press the DATA 10s push button. To clear display,
simply press any other push button.
Tap DOWN (or Range UP) indicator (
t-dnt-dn
t-dnt-dn
t-dn) – Shown at the end of a weld sequence if the
weld control is unable to compensate and maintain the programmed CURRENT. In this
case, moving the tap selector, if exists, to a lower setting will allow the control to maintain
the current constant. If machine is already at the lowest tap setting, the maximum current
range of machine is higher than the programmed range in
rr
rr
r
.A..A.
.A..A.
.A. In this case, choose a higher
current range from Table 8-1 and program the corresponding value in
rr
rr
r
.A..A.
.A..A.
.A.
PHASE SHIFT in [%] and RMS CURRENT in [kA] are also available during this condition.
To show PERCENT while
t-dnt-dn
t-dnt-dn
t-dn is displayed, simply press the DATA 1s push button. To
show the RMS CURRENT in [kA], simply press the DATA 10s push button. To clear display,
simply press any other push button.
8.3.1 USING CONSTANT CURRENT PROCESS OUTPUTS
The EN1001, while in any CONSTANT CURRENT mode, can be programmed to always provide
a weld current readout at the end of any weld sequence, no matter what is shown on display
before beginning of sequence. Several CONSTANT CURRENT PROCESS OUTPUTS function
as defined in Section 5.4.7 and can be programmed to function as explained below.
To obtain an End of Sequence Readout, find
PP
PP
P
.O..O.
.O..O.
.O. in EXTENDED FUNCTIONS and program
a value of
PP
PP
P
.O..O.
.O..O.
.O.=
1212
1212
12. While in CONSTANT CURRENT mode, control will measure the value
of current maintained during the weld and show this value on DATA display at the end of
the sequence. If limit window is being monitored for HI/LO range, the value shown on the
display will be the CURRENT maintained by control if it can maintain this value. If the
control cannot maintain the set CURRENT value, the control will flash
L.o.L.o.
L.o.L.o.
L.o. or
H.i.H.i.
H.i.H.i.
H.i.
(depending on the case).
To obtain an End of Sequence Readout and PROCESS OUTPUT valve (Valve 3) alarm
output, find
PP
PP
P
.O..O.
.O..O.
.O. in EXTENDED FUNCTIONS and program a value of
PP
PP
P
.O..O.
.O..O.
.O.=
1313
1313
13. While in
CONSTANT CURRENT mode, control will measure the value of current maintained during
the weld and show this value on DATA display at the end of the sequence. If limit window
is being monitored for HI/LO range, the value shown on the display will be the CURRENT
maintained by control if it can maintain this value. If the control cannot maintain the set
CURRENT value, the control will flash
L.o.L.o.
L.o.L.o.
L.o. or
H.i.H.i.
H.i.H.i.
H.i. (depending on the case). In addition,
the control will turn Valve 3 ON for 0.5 seconds (30 cycles).
8.3 DISPLAYING CURRENT AFTER WELD SEQUENCE (cont.)