ENTRON Controls, LLC. • 700120S • Page 145
Initiate the control using the FS3 terminal input ONLY. Bring the heads together on a previously
welded part. Hold the initiation contacts closed while the machine sets up the CONSTANT
CURRENT parameters. When a Primary Sensing Coil is used, this initiation will cause the
control to fire several times then count down on the Dial Plate from
9999
9999
99 (
9999
9999
99,
9898
9898
98,
9797
9797
97,..., to
2020
2020
20). The
display will switch to schedule 00 when the CONSTANT CURRENT routine has completed
successfully.
Setup must be run in SPOT welding mode. When setting up this control on a seam welder, the
EXTENDED FUNCTION parameter for SEAM mode should be set to
S.E.S.E.
S.E.S.E.
S.E.=
0000
0000
00. If welding
very thin gauges of material (20 Ga. or thinner), setup could be done without a coupon, wheel
to wheel. If operating a seam welder, stop the motor which turns the wheels.
NOTICE
APPENDIX B PROGRAMMING AND SETUP (cont.)