Page 120
Epson Research and Development
Vancouver Design Center
S1D13706 Hardware Functional Specification
X31B-A-001-08 Issue Date: 01/11/13
8.3.7 Miscellaneous Registers
bit 7 Vertical Non-Display Period Status
This is a read-only status bit.
When this bit = 0, the LCD panel output is in a Vertical Display Period.
When this bit = 1, the LCD panel output is in a Vertical Non-Display Period.
bit 3 Memory Controller Power Save Status
This read-only status bit indicates the power save state of the memory controller.
When this bit = 0, the memory controller is powered up.
When this bit = 1, the memory controller is powered down and the MCLK source can be
turned off.
Note
Memory writes are possible during power save mode because the S1D13706 dynamical-
ly enables the memory controller for display buffer writes.
bit 0 Power Save Mode Enable
When this bit = 1, the software initiated power save mode is enabled.
When this bit = 0, the software initiated power save mode is disabled.
At reset, this bit is set to 1. For a summary of Power Save Mode, see Section 15, “Power
Save Mode” on page 149.
Note
Memory writes are possible during power save mode because the S1D13706 dynamical-
ly enables the memory controller for display buffer writes.
bit 0 Reserved.
This bit must remain at 0.
Power Save Configuration Register
REG[A0h] Read/Write
Vertical Non-
Display
Period Status
(RO)
n/a
Memory
Controller
Power Save
Status (RO)
n/a
Power Save
Mode Enable
7 6 5 432 10
Reserved
REG[A1h] Read/Write
n/a Reserved
7 6 5 4 3 2 10