Page 18
Epson Research and Development
Vancouver Design Center
S1D13706 13706CFG Configuration Program
X31B-B-001-03 Issue Date: 01/03/29
Panel Power Tab
The S5U13706B00C evaluation board is designed to use the GPO signal to control the LCD
bias power. The following settings allow configuration of the necessary delays.
Power Down Time Delay This setting controls the time delay between when the
LCD panel is powered-off and when the S1D13706
control signals are turned off. This setting must be
configured according to the specification for the panel
being used.
This value is only used by Epson evaluation software
designed for the S5U13706B00C evaluation board.
Power Up Time Delay This setting controls the time delay between when the
S1D13706 control signals are turned on and the LCD
panel is powered-on. This setting must be configured
according to the specification for the panel being used.
This value is only used by Epson evaluation software
designed for the S5U13706B00C evaluation board.
Power Down
Time Delay
Power Up
Time Delay