Epson Research and Development
Page 87
Vancouver Design Center
Hardware Functional Specification S1D13706
Issue Date: 01/11/13 X31B-A-001-08
1. Ts = pixel clock period
Table 6-31: 320x240 Epson D-TFD Panel Horizontal Timing
Symbol Parameter Min Typ Max Units
t1
FPLINE pulse width 9 Ts (note 1)
t2
FPLINE falling edge to FPSHIFT start position 8.5 Ts
t3
FPSHIFT active period 331 Ts
t4
FPSHIFT start to first data 6 Ts
t5
Horizontal display period 320 Ts
t6 Last data to FPSHIFT inactive 5 Ts
t7
FPLINE falling edge to GPIO4 first pulse falling edge 1 Ts
t8
Horizontal total period 400 Ts
t9 GPIO4 first pulse falling edge to second pulse falling edge 200 Ts
t10 GPIO4 pulse width 11 Ts
t11 GPIO1 pulse width 100 Ts
t12 GPIO1 low period 100 Ts
t13 GPIO0 pulse width 200 Ts
t14 GPIO6 low pulse width 90 Ts
t15 GPIO6 rising edge to GPIO0 falling edge 10 Ts
t16 GPIO2 toggle to GPIO3 toggle 1 Ts
t17 GPIO5 low pulse width 7 Ts