Epson Research and Development
Page 11
Vancouver Design Center
S5U13706B00C Rev. 1.0 Evaluation Board User Manual S1D13706
Issue Date: 01/02/23 X31B-G-004-04
3.2 Configuration Jumpers
The S5U13706B00C has seven jumper blocks which configure various setting on the
board. The jumper positions for each function are shown below.
JP1 - GPIO0 Connection
JP1 selects whether GPIO0 is connected to SW1-9. SW1-9 is used to enable hardware video
invert on the S1D13706.
When the jumper is on (position 1-2), SW1-9 controls the hardware video invert feature
(default setting).
When the jumper is off, the hardware video invert feature is disabled. This setting must be
used for HR/TFT and D-TFD panels as GPIO0 is required in each panels LCD interface pin
mapping. Refer to the S1D13706 Hardware Functional Specification, document number
X28B-A-001-xx for details.
Note
When configured for Sharp HR-TFT or Epson D-TFD panels, JP1 must be set to no
jumper and JP6 must be set to position 2-3.
Figure 3-2: Configuration Jumper (JP1) Location
Table 3-2: Jumper Summary
Jumper Function Position 1-2 Position 2-3 No Jumper
JP1 GPIO0 Connection
GPIO0 connected to SW1-
9 for hardware video invert
—
GPIO0 disconnected from
SW1-9 for direct
HR/TFT/D-TFD or GPIO
testing
JP2 CLKI2 Source
MCLKOUT from clock
synthesizer
External oscillator (U5) —
JP3 CLKI Source
VCLKOUT from clock
synthesizer
External oscillator (U6) —
JP4 GP0 Polarity on H1
Normal (Active High) Inverted (Active Low) —
JP5
Contrast adjust for +ve LCD bias
(VDDH)
Software controlled
Manual controlled —
JP6 LCD Panel Voltage
+5V LCDVCC +3.3V LCDVCC —
JP7
Contrast adjust for -ve LCD bias
(VLCD)
Software controlled —
Manual controlled
= recommended settings
JP1
GPIO0 connected
GPIO0 disconnected
to SW1-9