3025EMC Master Control Switching & Channel Branding
Page 132 Revision 3.0.3
Tally remains when protected: This checkbox allows the user to configure if the panel will show
tally (status) when the panel is in a “channel protect mode”.
Parking Position: This is a key that can be used as a ‘parking’ space to reflect and copy the
functionality of a particular key. In order to copy a key functionality to this position, select
the key to copy and then press ‘p’ or ‘P’, this then moves the key type and number to the
parked key (not affecting the copied key). To move the parked key to another key, select
the key to be changed and press either ‘u’ or ‘U’. After each ‘u’ key press the key number
is automatically incremented if the key type is a source key.
Configure Primary Menu:
Primary Menus are defined as main menus on the control panel. These typically represent major
functional categories of controls.
Configure Secondary Menu:
Secondary Menus are defined as sub-menus to the Primary Menus on the control panel. These
typically represent minor functional categories of controls.
6.3.4. QMC-CP-E LCD Properties
The LCD Properties tab allows users to configure the colour for various behaviors of the LCD buttons.
By default different key types use a 'standard set' of colours, but the user can change these colours on
an individual panel basis.
There are a number of standard key types that have colour configuration capability; these are shown in
greyed-out edit boxes within this section. Any key type not covered by these types will be configured by
the "Other Off" or "Other On" settings.
Key Type: This selects the key type that requires a colour change, when changing the
selection the current colour setting will change in the Colour selector.
Colour Selector: This will change the colour of the currently selected key type, when changing the
selection the colour setting shown in the greyed-out edit box will change to show
the result of the change.
Restore: This will restore all the key type colours to the Evertz standard.
Save Default: This will save the current colour settings as the default for any LCD panels that are
created subsequently.
Disable Learn mode on Primary Source Keys: This option allows for learn mode programming of
Primary Source Keys to be enabled/disabled on this panel.