Resend nametable on Channel Selection: When a channel is selected it will resend the nametable to
the panel that requested to control this channel. The nametable consists of
channel names, source names and market configuration.
Panels retain markets after initialization: This is used in conjunction with the above checkbox.
Because the nametable contains the market configuration, when the nametable
is resent to the panel any changes that were made to the markets manually on
the panel will be erased unless this setting is enabled.
7.6. AUTOMATION CONTROL
The 3025EMC can be connected to automation and scheduling systems to allow fully automatic
operation. The Switcher currently supports a protocol based on the GVG/Tektronix M2100 protocol,
which is Quartz RCP–37 protocol. This protocol has been tested with the following third party equipment:
(formerly DAL or Drake
Automation and Encoder)
Automation system, A7500
Automation system, Louth NT version
Automation system, MSL4000
Automation system , Compass, Morpheus
Some automation vendors will control all of the functionality available via the Quartz RCP-37, however,
some just support the standard commands from the original GVG protocol. Please contact your
automation vendor for more information. The EMC supports logging to help locate Automation/manual
control problems.