3025EMC Master Control Switching & Channel Branding
Revision 3.0.3 Page 195
9.2.3. GPO ACTIVATE
The corresponding EMC GPO will be active while the button is pressed and held. The EMC GPO MUST
be configured for “Manual GPO”.
The corresponding DCP GPO will be active while the button is pressed and held.
9.2.4. GPI TALLY
The corresponding EMCGPI will tally this button when the GPI is active. The EMC GPI Must be
configured to be “Panel GPI Tally”.
The corresponding DCP GPI will tally this button then the GPI is active.
9.3. UPGRADING THE 3025EMC FIRMWARE
There are three ways to upgrade the firmware on the 3025EMC, either using Overture Media Manager
software, ftp console or serial.
9.3.1. Overture Media Manager
1. Left Click on the 3025EMC device that you want to upgrade and then select View Media.
2. When the media list has been retrieved from the EMC, left click File then select “Upgrade…”
3. Navigate to the firmware required (.bin extension), confirm the filename and then select “Open”.
4. An upgrade dialogue box will be displayed that will confirm the firmware location, version and
build and creation date and time.
5. Confirm that the hardware status of the EMC is “Ready to Upgrade” and confirm if you want t
2.0.3he unit to reboot automatically when the upload of the new firmware file is completed.
6. Click “Upgrade” to proceed with the upgrade or “Cancel” to return to the Overture Media
Manger main dialogue window.
7. The progress of the firmware upload can be monitored using the Transfer Queue status in the
Status Window dialogue at the bottom of the Media Manager main window.
9.3.2. FTP Console
1. Open an anonymous ftp connection to the EMC (e.g. ftp 192.168.9.100 –A).
2. Type “cd app”.
3. Type “hash”.
4. Type “put “ and then drag the required firmware .bin file into the ftp console and press “Enter”.
5. The transfer of the firmware file to the app directory of the 3025EMC will proceed.