2. INSTALLATION
2.1. UNPACKING
Carefully remove the equipment from the boxes and check against the Packing List supplied with each
unit. This shows what items have been shipped against your order and includes all options. Any error
should be reported to your supplier immediately. After you have unpacked the equipment please save all
the packing material as this could be useful in the future if the unit needs to be returned for maintenance.
Check each item supplied for transit damage. Any damage should be reported in detail to your supplier.
You must state the serial number of the unit (to be found on the rear or side of each unit).
Standard remote panels are mains powered and must be checked to ensure that they have been set to
the correct mains (line) voltage. Instructions are to be found later in this section on how to change the
voltage.
2.2. INSTALLING AND REMOVING THE MODULES
2.2.1. Installing the Module Rear Plate
In most cases, the 3000FR or EMX6-FR or EMX3-FR (to be referred as EMC) frame will already have
the modules and rear plates installed within the frame. However, when modules and rear plates need re-
positioning, or when additional modules are purchased, proper module/rear plate installation is required.
Each EMC module is shipped with a matching rear panel plate that houses the appropriate connectors
for that module.
To Install the Rear Plate:
1. Locate the specific slot in the frame and remove any filler plates.
2. Install the rear plate over the open slot by first fitting the plate then tightening the two lock-screws.
3. Tighten the screws after the main module is installed.
CAUTION: If any of the screws for the rear plate are missing, please contact
Evertz immediately for the specification and/or replacement. Using the
incorrect screw can cause thread stripping.