Falcon M-Class | User Guide
236
Transmit Hold
Count
The number of BPDU's a bridge port can send per second.
When exceeded, transmission of the next BPDU will be delayed. Valid
values are in the range 1 to 10 BPDU's per second.
Advanced Settings
Edge Port
BDPU Filtering
Controls whether a port,
explicitly
configured as Edge, will transmit and
receive BPDUs.
Edge Port
BPDU Guard
Control whether a port, explicitly configured as Edge, will disable itself
upon reception of a BPDU.
The port will enter the error-disabled state, and will be removed from the
active topology.
Port Error
Recovery
Control whether a port in the error-disabled state automatically will be
enabled after a certain time.
If recovery is not enabled, ports have to be disabled and re-enabled for
normal STP operation.
This condition is also cleared by a system reboot.
Port Error
Recovery
Timeout
The time that has to pass before a port in the error-disabled state can be
enabled.
Valid values are between 30 and 86400 seconds (24 hours).
Buttons
Save:
Click to save changes.
Reset:
Click to undo any changes made locally and revert to previously saved
values.