Falcon M-Class | User Guide
348
4.23.4 RMON History Configuration
Configure RMON History table on this section. The entry index key is ID.
Figure 4-207: RMON History Configuration
Table 4-180: RMON History Configuration Parameters
Check to delete the entry. It will be deleted during the next save.
Indicates the index of the entry. The range is from 1 to 65535.
Indicates the port ID which has to be monitored. If in stacking switch,
the value must add 1000000*(switch ID-1), for example, if the port is
switch 3 port 5, the value is 2000005
Indicates the interval in seconds for sampling the history statistics data.
The range is from 1 to 3600, default value is 1800 seconds
Indicates the maximum data entries associated this History control
entry stored in RMON. The range is from 1 to 3600, default value is 50.
The number of data that shall be saved in the RMON.
Add New Entry: Click to add a new community entry
Save: Click to save changes.
Reset: Click to undo any changes made locally and revert to previously
saved values.