Falcon M-Class | User Guide
346
The method of sampling the selected variable and calculating the value to be
compared against the thresholds, possible sample types are:
Absolute: Get the sample directly.
Delta: Calculate the difference between samples (default).
The value of the statistic during the last sampling period.
The method of sampling the selected variable and calculating the value to be
compared against the thresholds, possible sample types are:
Rising Trigger alarm when the first value is larger than the rising threshold.
Falling Trigger alarm when the first value is less than the falling threshold.
RisingOrFalling Trigger alarm when the first value is larger than the rising
threshold or less than the falling threshold (default).
Rising threshold value (-2147483648-2147483647).
Rising event index (1-65535).
Falling threshold value (-2147483648-2147483647)
Falling event index (1-65535).
Add New Entry: Click to add a new community entry
Save: Click to save changes.
Reset: Click to undo any changes made locally and revert to previously saved
values.
4.23.2 RMON Event Configuration
Configure RMON Event table on this section. The entry index key is ID.
Figure 4-205: RMON Event Configuration
Table 4-178: RMON Event Configuration Parameters
Check to delete the entry. It will be deleted during the next save.
Indicates the index of the entry. The range is from 1 to 65535.
Indicates this event, the string length is from 0 to 127, default is a null
string.