DC powered models:
Required current rating = 2A
CAUTION DOUBLE POLE FUSING
Verify that the DC-Mains provide a 2 Amp double pole circuit breaker.
Required power conductor size = at least 0.75mm² for flexible cable or 1mm² for non flexible
Power Consumption (AC and DC Power Supplies):
µFalcon-MX
o Maximum <12W
o Typical: <10W
nFalcon-M:
o Maximum <20W
o Typical: <15W
Falcon-MX:
o Maximum <60W
o Typical: <50W
Falcon-MX device include Dual redundant, hot swappable power supplies