Remote Control
Remote Control Commands
6
6-33
Sound modulation frequency channel 3.
Analog MONO channel with NICAM.
Header:
S3MOD
ULATION
Data element:
OF
F/NRf
Suffix:
[
HZ
|
K
HZ |
M
HZ |
G
HZ]
Remark:
NRf
is a frequency of 0.5, 1.0, 3.0 kHz.
If no suffix is sent, the instrument sets HZ (Hertz).
This command is for NICAM only. The RSSF is not influenced.
Example:
S3MODULATION 3.0KHZ
or
S3MOD 3K
sets the sound modulation frequency for channel 3 to 3 kHz.
Sound Carrier amplitude, carrier 1
Header:
SC1L
EVEL
Data element:
OF
F/NRf
Suffix:
[
DBC
]
Remark:
NRf
is a level range from -5 to -15 dBc in step of 1 dB
Example:
SC1LEVEL -10DBC
or
SC1L -10
sets the sound carrier level 1 to -10 dB relative to the vision carrier.
Sound Carrier amplitude, carrier 2 for analog stereo and NICAM
Header:
SC2L
EVEL
Data element:
OF
F/NRf:
Suffix:
[
DBC
]
Remark:
NRf
is a level of -20, -25, -27 dBc.
Example:
SC2LEVEL -20DBC
or
SC2L -20
sets the sound carrier level 2 to -20 dBc relative to the vision carrier.