Troubleshooting 351
Ghosting
Light-Induced Fatigue
Problem Action
The printed result has ghosting. If the type of the ghosting is positive ghost:
Replace the drum cartridge if you have a spare cartridge.
See also:
• "Replacing the Drum Cartridge" on page 385
• "Installing a Drum Cartridge" on page 388
If the problem persists, contact the Fuji Xerox local representative office or an
authorised dealer.
If the type of the ghosting is negative ghost:
Verify that the print media recommended for the printer is being used.
If you are using non-recommended print media, use the print media recommended
for the printer.
See also:
• "Ghost Control" on page 287
If the problem is solved, adjust the transfer bias.
If the problem persists, replace the drum cartridge if you have a spare cartridge.
Adjust the transfer bias.
1 On the operator panel, press the (System) button and select Admin Menu →
Maintenance → Adjust Transfer Unit.
2 Adjust the setting for the type of print media being used.
If the problem persists, contact the Fuji Xerox local representative office or an
authorised dealer.
Problem Action
The printed result has
light-induced fatigue pattern.
Replace the drum cartridge if you have a spare cartridge.
See also:
• "Replacing the Drum Cartridge" on page 385
• "Installing a Drum Cartridge" on page 388
If the problem persists, contact the Fuji Xerox local representative office or an
authorised dealer.