IP8820/IP8830/IP8840
Installer Guide
D-16
Section
Field Name
Description
type
Defines the protocol of the provisioning server
Valid values are 0 for TFTP or 1 for HTTPS
Default is 0 (TFTP).
cfg_downlaod
Enables download of configuration file from the provisioning
server.
Valid values are enable or disable.
Default is enable.
sw_downlaod
Enables download of firmware from the provisioning server.
Valid values are enable or disable.
Default is enable.
dhcp_get_tftp
Enables use of DHCP options 66 or 150 for definition of the
TFTP sever.
Valid values are enable or disable.
Default is enable.
dhcp_get_http
Enables use of HTTP/S DHCP option, default 160, for
definition of HTTP/S URL
Valid values are enable or disable.
Default is enable.
https_url
Defines the HTTP/S provisioning server URL
The valid value is a URL of less than 255 characters.
The default is blank.
https_opt
Defines the DHCP Option for the HTTP/HTTPS server URL.
Valid values are 1 to 255.
Default is 160.
https_id
Specifies the ID for authenticating to an HTTPS session.
The valid value is under 50 characters.
The default is blank.
https_password
Specifies the password for authenticating to an HTTPS
session.
The valid value is under 50 characters.
The default is blank.
https_macform
Specifies the filename of phone specific configuration file.
The name or path must include “$MAC”, which is replaced by
the MAC address during provisioning.
The valid value is a maximum of 50 characters and includes
“$MAC”.
The default is “$MAC”.
verifying_cert
Defines a hexadecimal value composed of a 3-bit field flag
for HTTPS certification verification. 0x01 checks valid
certification authority. 0x02 checks whether a server name is
valid. 0x04 checks whether a certification is expired.
Valid values are 0 to 7.
Default is ff
smartup_use
Enables Smart Update, to check for and download
configuration and/or firmware periodically.
Valid values are enable or disable.
Default is enable.
smartup_type
Defines the timing of Smart Upgrade as an interval or time of
day
Valid values are 1 for interval or 2 for daily
Default is 2
PROVISI
ON
smartup_interval
Specifies the interval, in seconds, between firmware checks.
Valid values are 0 to 86400 seconds.
Default is 3600.